TS-1311 Digital Tens/NMES Unit

TS-1311 Digital Tens/NMES Unit
Item:  
TS-1311

TS-1311 Digital Tens/NMES Unit

Special Features

  • Two Channels
  • 3 Treatment Modes (Alternating, Synchronous or Constant)
  • Adjustable Rate & Width
  • Adjustable Contraction/Relaxation Times
  • Adjustable Ramp Up/Down
  • Clear Protective Cap for Intensity Dials
  • Treatment Timer
  • Compliance Monitor
  • Last Setting Recall
  • Low Battery Indicator


Technical Specifications
  • Channels: Dual, isolated between channels
  • Waveform: Asymmetrical biphasic square pulse
  • Amplitude: Adjustable 0-80 mA (40 Volts) peak into 500 ohm load each channel
  • Pulse Rate: Adjustable 2-120 pulses per second (Hz)
  • Pulse Width: Adjustable 50-300 microseconds (us)
  • Ramp (up/down): Adjustable 1-8 seconds
  • On (Contraction) Time: Adjustable 2-99 seconds
  • Off (Relaxation) Time: Adjustable 2-99 seconds
  • Treatment Modes: Synchronous (S): Channels 1 and 2 stimulate ON and OFF together at the same time. ON and OFF times apply to both channels
  • Constant (C): Channels 1 and 2 stimulate ON continuously at the set pulse rate. ON time, OFF time and Ramp do not apply to either channel.
  • Alternating (A): Channel 1 stimulates ON first, then the stimulation immediately alternates to Channel 2. At the end of Channel 2 cycle, then both channels are OFF for the set OFF time..
  • Patient Compliance Timer: Records the last 60 individual treatment sessions, with up to 999 minutes per session, and can record the whole treatment time for all the cumulative sessions.
  • Treatment Timer: Adjustable 5-90 minutes in 5 minute increments, or Continuous. When the remaining treatment time is 5 minutes, the clock symbol will begin to flash every second.
  • Automatic Shutoff: When using timed treatment, the unit will shut off automatically when ended, but will beep every 10 seconds until the amplitude knob is turned off completely. Treatment can resume by turning the amplitude back on.
  • Last Setting Recall: Memorizes the last settings that were used and will recall these settings whenever the unit is turned back on. These settings will remain the same until they are changed.
  • Low Battery Indicator: Battery symbol will flash in the LCD display when battery power level falls below 6.5 volts, to alert user of needing a new battery soon.
  • Battery: One 9 Volt DC battery (heavy duty, alkaline, or rechargeable) Size: 100 (L) x 59 (W) x 24 (H)